SPECIFICATIONS
Technical product description
GENERAL
technology type | split heat pump water heater |
PHYSICAL
Heat pump ‘condenser unit’ dimensions | 12″ x 12″ x 24″ |
Storage tank options (gallons) | 65/80/120 |
Evaporator panel size | 32″ x 79″ |
Potable heat exchanger type | double walled |
Refrigerant | 134A; low GWP (global warming potential), Zero ozone depletion potential |
PERFORMANCE
Annualized COP (Boston) | 2.7 |
UEF per Energy Star criteria | 2.8 |
Heat pump electrical consumption | 600 watts |
Heat pump electrical requirements | 120vac, 15A circuit |
Tank temperature set point | 130f |
Operating temperature (outdoor) | -10f to 110f |
Nominal heat pump capacity | 8,000 BTU’s |
Sound rating | 48 dBA |
FIRST HOUR DELIVERY
65 Gallon Tank | 80 Gallon Tank | 120 Gallon Tank | |
120V Heat pump only/with mix valve | 48 /57 | 59 /70 | 80 /94 |
With 120V back up element/with mix valve | 63 /74 | 74 /87 | 97 /114 |
With 240V back up element/with mix valve | 79 /93 | 90 / 106 | 115 /136 |
APPROVALS
System | Energy Star |
Heat pump and storage tank | UL 174 and UL1995 or UL 60335-2-40 |
WARRANTIES
Whole System | 10 Years |